• 25 Kv 250A Apparatus Bushing Standard
  • 25 Kv 250A Apparatus Bushing Standard
  • 25 Kv 250A Apparatus Bushing Standard

25 Kv 250A Apparatus Bushing Standard

Application: Industrial, Power Station
Voltage: 25 Kv
Current: 250A
Insulation Material: Epoxy Resin
Sheath Material: Crosslinking
Material Shape: Round Wire
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
25 KV 250A
Wire Core Material
Red Copper Wire
Certification
ISO
Model
Atgz-25/250
Brand
Anhuang
Reference No.
Atgz-25/250
Transport Package
Carton
Specification
As standard drawing
Trademark
OEM&ODM
Origin
China
HS Code
8538900000
Production Capacity
10000/Month

Product Description

25 Kv 250A Apparatus Bushing Standard
Anhuang specialized in Elbow Surge Arrester, we supply high quality Elbow Surge Arrester. Our products accord with IEEE386, and IEC standards.

Standard:

DIN 47636-7-1990 Power cable with extension cones, separable, with Um below 35kV Sub-connector device size·

Exposed Semiconductor Sheaths for High - Voltage Cable Fittings and Detachable Insulated Connectors; IEEE.

IEC60502 Extruded insulated power cables with rated voltages from 1 kV (Um= 1.2 kV) to 30 kV (Um= 35 kV) and annex;

IEC61442 Test methods for accessories for power cables with rated voltages from 6kV (Um= 7.2kV) to 30kV (Um= 35kV);
GB 12706-2002 Extruded insulated power cables with rated voltages from 1 kV(U m= 1.2 kV) to 35 kV (Um= 40.5 kV)And its annexes;

GB311.1-1997 high-voltage power transmission and distribution equipment with the insulation;

GB I T41.9.1999 high-voltage casing technical conditions;
GB11032.2010 AC non-gap metal oxide surge arresters; DIN 47636-7-1990 Power cables with extended cones, separable, with Um below 35kV Sub - connector device size.
 

Introduction:

25kV 250A Apparatus Bushing provide the interface for the 200A Cable connector and mostly used on the oil-insulated (R-temp, hydrocarbon, or silicone) apparatus, including switchgear, transformers, and capacitors.

The Apparatus Bushing are molded using high quality Epoxy Rubber, meet the requirement of standard EN50180/EN50181 DI N4 7636/HN52-S-61

Continuous Voltage Rating:

Item

15kV

25kV

35kV

Continuous operating voltage

8.7kV/15kV

12kV/20kV 18/20kV

26kV/35kV

AC withstand voltage

45kV/1min

55kV/5min

117kV/5min

DC withstand voltage

53kV/15mins

78kV/15mins

104kV/15mins

1.5/50 μ s Im pulse with stand voltage

95kV

125kV

215kV

Partial discharge voltage(<10PC)

13kV

20kV

45kV


Current Rating:

Item

250AMP

600AMP

Heat stable current

16kA 1S

30kA 2S

Peak withstand current

40kA

105kA


25 Kv 250A Apparatus Bushing Standard
Order Information:

 
Description Reference No. Length(A) Length(B)
24kV 250A Apparatus Bushing(standard) AH TGZ-24/250 224 108
24kV 250A Apparatus Bushing(short) AH TGZ-24/250S 189 73
24kV 250A Apparatus Bushing(long) AH TGZ-24/250L 284 168
25 Kv 250A Apparatus Bushing Standard
25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard
25 Kv 250A Apparatus Bushing Standard25 Kv 250A Apparatus Bushing Standard