• Fyn33 Type Four-Position Oil Immersed Load Break Switch
  • Fyn33 Type Four-Position Oil Immersed Load Break Switch
  • Fyn33 Type Four-Position Oil Immersed Load Break Switch
  • Fyn33 Type Four-Position Oil Immersed Load Break Switch
  • Fyn33 Type Four-Position Oil Immersed Load Break Switch
  • Fyn33 Type Four-Position Oil Immersed Load Break Switch

Fyn33 Type Four-Position Oil Immersed Load Break Switch

Application: Power, Electronic
Phase: Three
Core: Shell-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: High Voltage
Usage: Power Transformer
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FYN33-38
Frequency Characteristics
High Frequency
Shape of Core
High Voltage
Brand
Anhuang
Transport Package
Packing in Carton
Specification
ABF3I-25/630A Type Two-Position Oil Immersed Load
Trademark
OEM & ODM
Origin
China
HS Code
8504901900
Production Capacity
100 PCS/Month

Product Description

FYN33 Type Four-Position Oil Immersed Load Break Switch

Fyn33 Type Four-Position Oil Immersed Load Break Switch

   

Anhuang load break switch is a manually operated, two posiiton, 4 position, load make or break, oil immersed, single phase or three phase rotary switch.

 

This type swith is apply to the composite transformers with 50Hz AC and rated voltage of 12kV and 35kV. It is a nice and small load switch designed to meet the challenge of continually raising the load capacity of power net while the composite transformers usually have a very limited internal space. It uses the transformer oil as the media of insulation and that for preventing the electric arc. It uses a mechanical spring for reserving energy. Three phase linkage is available with it. Also it can promptly and accurately turn on or cut off the electric current. This switch can be applicable to any power distribution system with 12kV and 35kV and double power supply lines.

Main technical parameters
Fyn33 Type Four-Position Oil Immersed Load Break Switch
 
Overall dimension 
Fyn33 Type Four-Position Oil Immersed Load Break Switch
Reservation installation size for transformer housing 
Fyn33 Type Four-Position Oil Immersed Load Break Switch

Load switch installation

    Before installation, please check whether the switching motion is flexible and accurate carefully, only after confirmed to be under good condition, the installation can be implemented, in addition, the load switch must be dried under 65±5ºCcondition by 24h.

Fyn33 Type Four-Position Oil Immersed Load Break SwitchFyn33 Type Four-Position Oil Immersed Load Break SwitchFyn33 Type Four-Position Oil Immersed Load Break Switch

5) After installation and connection, it is suggested to carry out "open" and "close" operation to check if the switch can be moved flexibly and if the position indication is correct, if any abnormal, please check the installation of switch and the connection of busbar according to article 2 and 4.
 

Points for attention

 

1) This load switch can be used to open or close rated current only, while the application for closing and opening the failure current. If over rated current, forbidden to operate switch.

2) Only the special insulated operating arm can be used to operate this load switch to ensure personal safety.

 

Connection Diagram 