• Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet
  • Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet
  • Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet

Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet

Type: Distribution Metering Box
Shell Material: Steel Plate
Installation: Fixed
Transport Package: Air Transportation, Sea Transportation
Specification: 1 Uint
Origin: China
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XGN15-12(F)
HS Code
8537209000

Product Description


Product overview:
Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet
XGN15-12(F), HXGN15-12(F·R) box type fixed AC metal closed switchgear (hereinafter referred to as "switchgear"), used in the rated voltage 12kV, rated current 630A and below the ring grid power supply or radiation power supply system, especially suitable for pre-installed substation as the control and protection of power system. This product is equipped with FLN36-12D type sulfur hexaoxide load switch or FLRN36-12D type load switch-dissolver combination electrical appliance, which has the characteristics of small size, light weight, easy operation, light operation force, reliable interlocking, maintenance-free and so on. It is a new generation of high-voltage switchgear required for urban power grid transformation and construction.
This product conforms to: GB3906 "3~35kV AC metal closed switchgear", GB/T11022 "high voltage switchgear and control equipment standard common technical requirements",IEC298 "rated voltage 1kV Above 50kV and below AC metal closed switchgear and Control Equipment ",DI/T404 "Indoor AC High voltage Switchgear ordering Technical Conditions" standards.
Main Technical specifications Serial number of the main technical specifications of the switch cabinet

Applicable conditions:

1   Ambient air temperature:-15ºC~+40ºC
2   Altitude :1000m and below,
3   Humidity Case:
     The daily mean value is not more than 95%, and the daily mean value of water vapor pressure is not more than 2.2kPa;
     The monthly mean value is not more than 90, and the monthly mean steam pressure is not more than l.8kPA.
4  Seismic intensity,not more than 8 degrees.
5  There is no obvious pollution such as turbid or combustible gas.
Note: Users may negotiate with the Company when the above normal conditions of use are exceeded.

structure:

Switchgear is composed of cabinet, main switch (SF6 load switch or combined appliance),ground switch, instrument room,bus and other electrical components and auxiliary components.
The cabinet body is made of aluminum zinc steel plate by modular forming assembly. The backside of the cabinet is provided with a pressure relief channel to protect the operator in case of internal
faiture.The bus in the bus room is covered with insulation and directly connected to the wiring terminals of the load switch. The three phase bus is arranged longitudinally, so that the switchgear can be arbitrarily extended from left to right and easy to change its layout.The instrument room is located in the upper part of the switching equipment,which can be equipped with ammeter,voltmeter,indicator light and electric operating mechanism.

Technical Parameters:

Main Technical specifications Serial number of the main
Number Name Unit HXGNl5-12 (F) HXGNl5-12 (F·R)
1 Rated voltage V 12 12
2 Ratec frequency Rated Hz 50 50
3 Main busbar rated current A 630 630
4

Maximum rated current of fuse

A - 125
5

The main circuit is rated for short-time current tolerance/
Rated short circuit duration

KA/S 20/3 20/3
6

Rated expected short-circuit breaking current

KA - 50
7 1min

power frequency withstand voltage ,phase to phase,to earth

KV 42/48 42/48
8

Ground shock withstand voltage ,phase to phase,to earth

KV 75/85 75/85
9 level of protection   IP2X IP2X

Main switch inside switchgear(SF6 load switch and combined appliance )technical specification
 
Number Name Unit HXGNl5-12 (F) HXGNl5-12 (F·R)
1

The ground circuit is rated as a short-time tolerant current source

KA/s 20/2 20/2
2 Rated peak tolerable current &

Rated short-circuit closing current

KA 50 125
3 Main busbar rated current A 630 630
4

Maximum rated current of fuse

A 630 630
5

The main circuit is rated for short-time current tolerance/
Rated short circuit duration

A 31.5 31.5
6

Rated expected short-circuit breaking current

A 10 10
7 1min

power frequency withstand voltage ,phase to phase,to earth

KVA - 1250
8

Ground shock withstand voltage ,phase to phase,to earth

A - 1700
9 level of protection time 2000 2000



About US:
Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet
Xgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage CabinetXgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage CabinetXgn15-12 (F) Switch Gear Ring Main Unit Switchgear Medium Voltage Cabinet





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.