• Wst Series Linear Type off Load Tap Changer
  • Wst Series Linear Type off Load Tap Changer
  • Wst Series Linear Type off Load Tap Changer
  • Wst Series Linear Type off Load Tap Changer
  • Wst Series Linear Type off Load Tap Changer
  • Wst Series Linear Type off Load Tap Changer

Wst Series Linear Type off Load Tap Changer

Type: High-voltage
Structure: Single-column Disconnector
Installation: Indoor High-voltage
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Wst Series Linear Type off Load Tap Changer pictures & photos
Wst Series Linear Type off Load Tap Changer
US $20-50 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
WST
Operation
Electric
Grounding Mode
Grounding
Number of Poles
Three Pole
Grounding
Single Ground
Series
4*3/5*6/7*8
Common Model
Wst
Structure of Operating
Electric
Brand
Anhuang
Shape of Core
High Voltage
Model Number
Wst
Shipping
by Sea/ Express
Use for
Transform
Transport Package
Packing in Carton
Specification
As standard drawing
Trademark
OEM & ODM
Origin
Zhejiang China
HS Code
8538900000
Production Capacity
10000/Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
10.000kg

Product Description

Product Introduction:
 
Wst Series Linear Type off Load Tap Changer
Wst Series Linear Type off Load Tap Changer

This instruction is suitable for strip-type off-circuit tap changer with its frequency of 50, 60Hz, rated current 63A and below , and rated voltage 33kV(Called tap changer below). This tap changer is used in the oil-immersed power transformer and being operated under off-circuit state.


Usage:

1. The tap changer should be working within the ambient temperature specitied as table l
 
Dielectric medium Temperature ºC
Lowest temperature Highest temperature
Air -25 40
Oil -25 100
                                              table 1

2.There should be no explosive and corrosive air around installation place.
 
Dimension:

Surface dimension and installaeion dimension of the tap changer (see Figure1 and table 2).
Wst Series Linear Type off Load Tap ChangerWst Series Linear Type off Load Tap Changer
                                                  Tbble 2




Installation:

1 Before we install a tap changer, please check each part of the tap changer if they are all right, then the tap changer must be taken dry treatment. The operation method is the same as the method of winding

2 Double sealing type is adopted between the tap changer and the tank cover:
That is a sealing washer is put on the lower part of the tank cover, and another

3 When installation of switch, please open the switch cover, press the springgasket, rotate 90°and pull out the gasket. Then dismantle the hand shank and fixed plate, pull out the screw nut, and take out the seal gasket, push out the switch from the tank bottom and put the other seal gasket and pressing ring on the bottom of tank.Then reinstall all the spares above mentioned back.

• Note: After installation, the indicator of tap position should fit for the actual tap position of the switch.


Operation:

The tap changer can be operated when the power transformer is under off-circuit state.

When you operate the tap changer, please lift up the handle shaft, make the locating block on the locating shaft get away from the locating trough on the locating tray, turn round the handle shaft to the needed position then put the locating block on the locating shaft to the relevant locating trough.

After the tap changer has been taken dry treatment, Don't turn it if no oil in the switch.


Notice :

If the tap changer has oil leakage phenomenon, you must check the leakage position first, if the leakage is from the turning axle, please screw up the plug on the axle, if the leakage is from the tank cover, you should screw up the solid nut on the flange.


COMPANY PROFILE:

ANHUANG ELECTRIC POWER

COMPANY PROFILE
ANHUANG is a modern company of professional design and manufacture of3.6kV to 40.5kV Medium Voltage cable accessories, electric components and whole set cabinet.
Subsidiaries:
Anhuang Electric Power Technology Co.,Ltd
Zhejiang Anhuang Imp.& Exp.Co,Ltd.

We provide high quality, low cost products for utility systems worldwide.
Our professional production testing equipment, special production technology and professional service team can satisfy the customers' demand.
Our professional engineers, technicians and managers team always keep our promise: ANHUANG is not only provide cost-effective high quality products but also provide high quality, efficient, fast service and technical support to ensure customers' require. Our company obtained international quality management system certification forISO9001,ISO1401OHSAS18001
Our company adhering to the 'safety electricity, forever brilliant' as our enterprise's humanism Willing to work with you hand in hand to build better future.
Wst Series Linear Type off Load Tap Changer

 

Wst Series Linear Type off Load Tap ChangerWst Series Linear Type off Load Tap ChangerWst Series Linear Type off Load Tap Changer
Wst Series Linear Type off Load Tap Changer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Wst Series Linear Type off Load Tap Changer pictures & photos
Wst Series Linear Type off Load Tap Changer
US $20-50 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
113
Year of Establishment
2014-05-05